8.5 Digit Digital Multimeter
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a 8.5 digit Digital Multi-function Meter (DMM).
This ILC/PT Kit contains a 8.5 digit DMM. Participants will use their lab practices to perform 15 measurements of voltage and current. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
**TRAVEL KIT: This kit travels with the 3458A/DC, should you decide to participate in the 3458A/AC, there is an additional $300 fee per ILC/PT.
8.5 Digit Digital Multimeter
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a 8.5 digit Digital Multi-function Meter (DMM).
This ILC/PT Kit contains a 8.5 digit DMM. Participants will use their lab practices to perform 15 measurements of voltage and current. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
**TRAVEL KIT: This kit travels with the 3458A/AC, should you decide to participate in the 3458A/DC, there is an additional $300 fee per ILC/PT.
AC Watt Transducer Kit
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a AC Watt Transducer.
This ILC/PT Kit contains a AC Watt Transducer. Participants will use their lab practices to perform 5 measurements of voltage and current. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with calibration of, have appropriate lab equipment and have measurement uncertainties appropriate for calibration of similar devices.
Capacitors
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to the calibration of Fixed Capacitors.
This ILC/PT Kit consists of seven GenRad capacitors in the range of 0.001 µF to 0.5 µF. Participants are expected to be able to characterize each capacitor and report the measured values within their reported uncertainties. The frequency of test will be at 1 KHz.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
RMS Clamp Meter
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participants practices, training, and measurement uncertainty relating to the calibration of a typical Clamp Meter.
This ILC/PT Kit contains a multifunction Clamp Meter. Participants will perform 10 measurements across functions of AC & DC Voltages up to 150 V, AC & DC Clamp Current up to 500 A, and Resistance. The artifact resolution is 0.1 Units.
Participants are expected to be familiar with the operation and calibration of Multifunction Clamp Meters, have all necessary lab equipment, and have measurement uncertainties appropriate for calibration of similar devices.