Humidity Sensor Kit for Generation Chamber
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a Humidity Sensor via generating humidity in a chamber.
No other means of humidity generation is allowed for this ILC, i.e. salt solutions. If your organization does not simulate humidity via this method you are instructed not to participant in this ILC. NAPT has designed additional Humidity ILC/PT's for other methods. Make sure you are participating in the correct ILC/PT for your method of humidity generation.
Artifact chosen for this ILC has a range of 0 to 100 %RH. Accuracy of artifact is 1% RH. Initial reference laboratory calibration of test artifact was performed at 21.7 C. calibration of a Humidity Sensor with indicator.
This ILC/PT Kit contains a Digital Humidity Indicator with sensor. Participants will use their lab practices to perform 7 measurements of Relative Humidity percent from 10.00 to 90.00 %RH. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
KITS, Thermodynamic
HUMIDITY-GC-518
Humidity Sensor Kit for Generation Chamber
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a Humidity Sensor via generating humidity in a chamber.
No other means of humidity generation is allowed for this ILC, i.e. salt solutions. If your organization does not simulate humidity via this method you are instructed not to participant in this ILC. NAPT has designed additional Humidity ILC/PT's for other methods. Make sure you are participating in the correct ILC/PT for your method of humidity generation. Artifact chosen for this ILC has a range of 0 to 100 %RH. Accuracy of artifact is 1% RH. Initial reference laboratory calibration of test artifact was performed at 21.7 C. calibration of a Humidity Sensor with indicator.
This ILC/PT Kit contains a Digital Humidity Indicator with sensor. Participants will use their lab practices to perform 7 measurements of Relative Humidity percent from 10.00 to 90.00 %RH. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
KITS, Thermodynamic
HUMIDITY-GC-622
Humidity Sensor Kit for Generation Chamber
The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a Humidity Sensor via generating humidity in a chamber.
No other means of humidity generation is allowed for this ILC, i.e. salt solutions. If your organization does not simulate humidity via this method you are instructed not to participant in this ILC. NAPT has designed additional Humidity ILC/PT's for other methods. Make sure you are participating in the correct ILC/PT for your method of humidity generation. Artifact chosen for this ILC has a range of 0 to 100 %RH. Accuracy of artifact is 1% RH. Initial reference laboratory calibration of test artifact was performed at 23 degrees C.
This ILC/PT Kit contains a Digital Humidity Indicator with sensor. Participants will use their lab practices to perform 7 measurements of Relative Humidity percent from 10.00 to 90.00 %RH. Measurement values will be appropriate for calibration of similar devices.
Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
Humidity Sensor Kit for Salt Solution
The purpose of this ILC/PT is to demonstrate laboratory ability to make humidity measurements by means of calibration of a Humidity Sensor via reference salt solutions.
No other means of humidity generation is allowed for this ILC, i.e. generation of humidity in a chamber. If your organization does not simulate humidity via this method you are instructed not to participant in this ILC. NAPT has designed additional Humidity ILC/PT's for other methods. Make sure you are participating in the correct ILC/PT for your method of humidity generation.
Hart Scientific PRT
The intent of this ILC/PT is to give organizations an opportunity to demonstrate proficiency in the calibration of a four terminal Platinum Resistance Thermometer.
Participants are requested to make eleven measurements from -196 to 410 C. The probe should be immersed to a minimum depth of 4".
The pivot lab uncertainty ranges from 7.2 mK to 18 mK.
Participants are expected to be familiar with this device and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.
Artifact in kit: Fluke, 5615 (1/4" diameter probe)