Fixed Volume Pipettes (50 µL to 1000 µL)

The primary purpose of the Pipette-621 is to determine the appropriateness and effectiveness of the participant’s equipment, procedures, training, and measurement uncertainty calculations relating to the measurement of POVA (Piston-operated volumetric apparatus) also known as Piston Pipettes.

By participating in this ILC organizations have an opportunity to demonstrate their proficiency (e.g., use of appropriate equipment, procedures, ability to follow instructions) in the calibration of a POVA. By participating, participants will demonstrate technical competence for the parameters associated with a POVA. Associated reported uncertainties will also be evaluated as part of this ILC/PT. 

This kit includes 5 Fixed Volume Pipettes ranging from 50µL to 1000µL.

Show Details Inquire
KITS, Other Mechanical

Accelerometer

ILC/PT Vibration 106/206/406 Kit contains three different transducers (1 Voltage type, 1 Charge type, and 1 Strain Gauge or Capacitive type). Participants have the option of completing one or more accelerometers, based on their capability.

It is intended to demonstrate technical competence for measurement, calibration, control and operation of an accelerometer calibration system utilized for calibration of various vibration transducers. Participant is expected to make a total of 16 measurements (for each accelerometer) between the ranges of 1 g to 10 g and 10 Hz to 10 kHz. This ILC is to be reported in mV/g.  

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

**TRAVEL KIT: This kit travels with the VIBRATION-106 and VIBRATION-206, should you decide to participate in either or both ILC/PTs there is an additional $100 fee per ILC/PT.

Show Details Inquire
KITS, Other Mechanical

Accelerometer

ILC/PT Vibration 106/206/406 Kit contains three different transducers (1 Voltage type, 1 Charge type, and 1 Strain Gauge or Capacitive type). Participants have the option of completing one or more accelerometers, based on their capability.

Participants have the option of completing one or more accelerometers, based on their capability. It is intended to demonstrate technical competence for measurement, calibration, control and operation of an accelerometer calibration system utilized for calibration of various vibration transducers. Participant is expected to make a total of 16 measurements (for each accelerometer) between the ranges of 1 g to 10 g and 10 Hz to 10 kHz. This ILC is to be reported in pC/g.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

**TRAVEL KIT: This kit travels with the VIBRATION-106 and VIBRATION-406, should you decide to participate in either or both ILC/PTs there is an additional $100 fee per ILC/PT.

Show Details Inquire
KITS, Other Mechanical

Accelerometer

ILC/PT Vibration 106/206/406 Kit contains three different transducers (1 Voltage type, 1 Charge type, and 1 Strain Gauge or Capacitive type). Participants have the option of completing one or more accelerometers, based on their capability.

It is intended to demonstrate technical competence for measurement, calibration, control and operation of an accelerometer calibration system utilized for calibration of various vibration transducers. Participant is expected to make a total of 16 measurements (for each accelerometer) between the ranges of 1 g to 10 g and 10 Hz to 10 kHz. This ILC is to be reported in pC/g.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

**TRAVEL KIT: This kit travels with the VIBRATION-206 and VIBRATION-406, should you decide to participate in either or both ILC/PTs there is an additional $100 fee per ILC/PT.

Show Details Inquire
KITS, Other Mechanical

Test Blocks

The intent of this ILC/PT is to give organizations an opportunity to demonstrate proficiency in the discipline of hardness calibration. This ILC/PT Kit contains a set of six Rockwell Testblocks.

Participant laboratories will need to warm up their hardness tester using their own blocks, and are asked to make a total of 6 measurements between the ranges of 45 to 100 HRBw and 20 to 65 HRC. 

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Inquire
KITS, Other Mechanical

Tachometer/Stopwatch

The intent of this ILC/PT is to provide a means for laboratories to evaluate practices, training, and measurement uncertainties in the calibration of timing parameters. This kit includes a digital tachometer and stopwatch.

Tachometer Contact resolution is 0.1 rpm up to 9,999.9 rpm; Non-Contact resolution is 1 rpm up to 99,999 rpm. Stopwatch resolution is 0.001 seconds.

Participants are asked to make 12 measurements, consisting of Contact from 500 to 6,000 rpm; non-Contact from 1,000 to 40,000 rpm; and time from 60 to 86,400 seconds.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Artifacts in kit:

Tachometer: Shimpo - DT-205LR 

Stopwatch: Control Company - 1051 (94460-28)

Show Details Inquire
KITS, Other Mechanical

Tachometer/Stopwatch

The intent of this ILC/PT is to provide a means for laboratories to evaluate practices, training, and measurement uncertainties in the calibration of timing parameters. This kit includes a digital tachometer and stopwatch.

Tachometer Contact resolution is 0.1 rpm up to 9,999.9 rpm; Non-Contact resolution is 1 rpm up to 99,999 rpm. Stopwatch resolution is 0.001 seconds.

Participants are asked to make 12 measurements, consisting of Contact from 500 to 6,000 rpm; non-Contact from 1,000 to 40,000 rpm; and time from 60 to 86,400 seconds.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Artifacts in kit:

Tachometer: Shimpo - DT-205L

Stopwatch: Robic - SC-505

Show Details Inquire
KITS, Other Mechanical

Surface Finish

The purpose of this ILC/PT is to give organizations an opportunity to demonstrate their proficiency in the measurement of surface finish using appropriate equipment, procedures, and their ability to follow measurement instructions. 

This ILC/PT Kit contains three artifacts with varying surface parameters.  Participants will use their lab practices to perform surface finish Ra measurements in the range of 12 µin to 118 µin. Measurement values will be appropriate for measurement of similar surfaces.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Inquire
KITS, Other Mechanical

Roundness

The intent of this ILC/PT is to provide a means for laboratories to determine the appropriateness and effectiveness of participants practices, training, and measurement uncertainty calculations relating to the measurement of Roundness. This ILC/PT contains a 1 inch Class XXX Plain Plug.

Participants are asked to make roundness measurements at three locations. Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Inquire
KITS, Other Mechanical

Mass Weight Set / Class F

The primary purpose of this ILC/PT is to provide a means and opportunity for participants to demonstrate their proficiency (e.g. effective and appropriate use of the participant’s equipment, procedures, methods, and measurement uncertainty, and the ability to follow instructions) in the calibration of a Class F weight set.  

By participating, participants will demonstrate technical competence for the measurement parameters associated with weights of similar size and weight class.  This weight set contains 10 weights ranging from 0.2 lb to 0.001 lb.

Participants will use their lab procedures to perform measurements of each weight in the set.

Participants are expected to be familiar with handling and calibration of mass standards, have all necessary auxiliary equipment to support the measurement, and have measurement uncertainties appropriate for the calibration of similar standards.

Mass weight set

Show Details Inquire
KITS, Other Mechanical

Mass Level Three-A

The primary purpose of this ILC/PT is to provide a means and opportunity for participants to demonstrate their proficiency (e.g. effective and appropriate use of the participant’s equipment, procedures, methods, and measurement uncertainty, and the ability to follow instructions) in the calibration of a Class F weight set.  

By participating, participants will demonstrate technical competence for the measurement of parameters associated with weights of similar size and weight class.  This weight set contains 6 weights ranging from 10 lb to 0.5 lb.

Participants will use their lab procedures to perform measurements of each weight in the set.

Participants are expected to be familiar with handling and calibration of mass standards, have all necessary auxiliary equipment to support the measurement and have measurement uncertainties appropriate for calibration of similar standards.

Show Details Inquire
KITS, Other Mechanical

Mass Level One

New class 1 - Pre-Qualification is required to participate in this ILC/PT. 

The primary purpose of this ILC/PT is to provide a means and opportunity for participants to demonstrate their proficiency (e.g. effective and appropriate use of the participant’s equipment, procedures, methods, and measurement uncertainty, and the ability to follow instructions) in the calibration of a Class 1 weight set.  

By participating, participants will demonstrate technical competence for the measurement of parameters associated with weights of similar size and weight class.  This weight set contains 10 weights ranging from 100 g to 500 mg. Participants will use their lab procedures to perform measurements of each weight in the set.

Participants are expected to be familiar with handling and calibration of mass standards, have all necessary auxiliary equipment to support the measurement and have measurement uncertainties appropriate for calibration of similar standards.

Show Details Inquire
KITS, Other Mechanical

Mass Weight Set

This program is intended to provide a means for the participant laboratory to validate the technical competence of the laboratory in the calibration of small weights. This ASTM Class 1 weight kit contains 9 items ranging from 1 g to 100 g.

Reference values and associated uncertainties are provided by an accredited laboratory who concentrates on these measurements. Reference uncertainties vary from 1.6 µg to 12 µg depending on size.

Participants are expected to be familiar with handling and calibration of precision weights and have appropriate lab equipment and  measurement uncertainties for calibration of similar weights.

Artifacts in kit: Troemner Gram Weights, 1g, 2g (x2), 5g, 10g, 20g (x2), 50g, 100g

mass weight set

Show Details Inquire