Skip to Main Content

How It Works

NAPT Makes the Process Simple

Step
01

Order Kits

Use our simple online order form or call (952) 303-6126.

Step
02

Receive Materials

The NAPT Sponsored ILC-PT Kit & any necessary accessories will be shipped to you. 

Step
03

Submit Data and Review Results

Use the convenient NAPT Customer Portal to submit your test results and access your reports.

Step
04

Ship Artifacts

We’ll provide an address to ship the kit to the next participant. 

Same Tests. Reduced Pricing. Members Save on Every Enrollment

NAPT Fee Structure

Members receive a 20% Discount on all purchases.

Service Regular Price NAPT Member Price
NAPT Sponsored ILC/PT $595 $476
Additional Tech $100 $80
Self-Managed Intra $395 $316
NAPT Assisted Intra $795 $636
Accreditation Manager $1,295 $1,036
Membership $350 N/A

Find a Kit

Over 100 NAPT Sponsored Kits to meet your proficiency testing needs.

Number of search result: 6

On Sale, Electrical-DC/Low Frequency DMM-1019
Q2 Reduced Pricing!

6.5 Digit Precision Multimeter

The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to calibration of a 6.5 digit Digital Multifunction Meter (DMM). 

This ILC/PT Kit contains a 6.5 digit DMM. Participants will use their lab practices to perform 16 measurements of voltage, current, 4-wire resistance, and frequency. Measurement values will be appropriate for calibration of similar devices. 

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Enroll
On Sale, Dimensional GAGE-201
Q2 Reduced Pricing!

Gage Block Set of 6

This six piece block set is intended for the participant to demonstrate technical competence in the calibration of longer gage blocks ranging from 3 in to 20 in. The associated reference uncertainties are in the order of 5 µin to 41 µin.

Show Details Enroll
On Sale, Other Mechanical MASS-417
Q2 Reduced Pricing!

Mass Weight Set / Class F

The primary purpose of this ILC/PT is to provide a means and opportunity for participants to demonstrate their proficiency (e.g. effective and appropriate use of the participant’s equipment, procedures, methods, and measurement uncertainty, and the ability to follow instructions) in the calibration of a Class F weight set.  

By participating, participants will demonstrate technical competence for the measurement parameters associated with weights of similar size and weight class.  This weight set contains 10 weights ranging from 0.2 lb to 0.001 lb.

Participants will use their lab procedures to perform measurements of each weight in the set.

Participants are expected to be familiar with handling and calibration of mass standards, have all necessary auxiliary equipment to support the measurement, and have measurement uncertainties appropriate for the calibration of similar standards.

Mass weight set

Show Details Enroll
On Sale, Pressure PRESSURE-311
Q2 Reduced Pricing!

1,000 psi Digital Pressure Gauge

The intent of this ILC/PT is to provide a means for participants to evaluate the appropriateness and effectiveness of their practices, training, and measurement uncertainty calculations relating to the measurement of Pressure, 0 to 1000 psi.
 

Participants are asked to perform 11 measurements, on increasing and decreasing scale from 0 to 1000 psi. Resolution of the digital artifact is 0.01 psi. Pressure medium - use only clean, dry non-corrosive gases (pneumatic). Manufacturer specification for artifact accuracy is 0.01% FS (FS = 1000 psi).

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Enroll
On Sale, Thermodynamic TEMP-DIGITAL-419
Q2 Reduced Pricing!

Digital Thermometer with Probe

The intent of this ILC/PT is to provide a means for the participant to evaluate the appropriateness and effectiveness of practices, training, and measurement uncertainty relating to calibration of a Digital Thermometer. 

This ILC/PT Kit contains a Digital Thermometer with Probe. Participants are asked to use their lab practices to make 4 measurements of temperature from -20 °C to 120 °C. UUT resolution is 0.01 °C. UUT manufacturer accuracy spec is +/- 0.012 °C. 

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Enroll

Theme picker

Proficiency Testing is Crucial

Proficiency testing plays a vital role in a lab’s quality assurance efforts and is required by major accrediting bodies. Routine testing can also benefit your lab in multiple other ways.

  • Maintain Accreditation
  • Ensure Technical Competence
  • Uphold Quality Standards
  • Monitor Lab Performance
  • Improve Processes
  • Maintain Accreditation
  • Ensure Technical Competence
  • Uphold Quality Standards
  • Monitor Lab Performance
  • Improve Processes