Skip to Main Content

How It Works

NAPT Makes the Process Simple

Step
01

Order Kits

Use our simple online order form or call (952) 303-6126.

Step
02

Receive Materials

The NAPT Sponsored ILC-PT Kit & any necessary accessories will be shipped to you. 

Step
03

Submit Data and Review Results

Use the convenient NAPT Customer Portal to submit your test results and access your reports.

Step
04

Ship Artifacts

We’ll provide an address to ship the kit to the next participant. 

Same Tests. Reduced Pricing. Members Save on Every Enrollment

NAPT Fee Structure

Members receive 20 % off on all purchases.

Service Regular Price NAPT Member Price
NAPT Sponsored ILC/PT $595 $476
Additional Tech $100 $80
Self-Managed Intra $395 $316
NAPT Assisted Intra $795 $636
Accreditation Manager $1,295 $1,036
Membership $350 N/A

Find a Kit

Over 100 full-service kits to meet your proficiency testing needs.

Number of search result: 5

On Sale, Electrical-RF/Microwave ATNR dB Loss-210
Q1 Reduced Pricing!

Attenuators Set of 5 Power Meter

The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to the calibration of RF Attenuators between 1 and 26.5 GHz.

This ILC/PT contains a set of 5 attenuators; each is a 20 dB, 3.5 mm device.

Participants will utilize their practices to perform 60 separate attenuation measurements, as they connect each device, perform dB Loss measurement at a predetermined four frequencies, remove the device, rotate the device per instructions, reconnect, perform measurements at the same four frequencies, remove and rotate the device again and reconnect to perform a third set of measurements. The average of the three measurements at each frequency is reported, and the entire process is repeated with the remaining 4 attenuators.

Show Details Enroll
On Sale, Dimensional CMM-208
Q1 Reduced Pricing!

Dimensional Inspection, Test Blocks

The intent of this ILC/PT is to provide a means for the participant to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to measuring of fabricated parts.

This ILC/PT Kit involves the use of a CMM to complete multiple measurements. Four special features are measured resulting in 14 unique measurements, including angles. Measurements range from 1.0 to 11.0 inches and approximately 35 degrees of angle. Expected resolution is 10 microns and 10 micro degrees of angle.          

Participants are expected to be familiar with the operation and of their CMM in the inspection and measurement of fabricated parts against design tolerances, have all necessary equipment, and have measurement uncertainties appropriate for measurement of similar devices.

Show Details Enroll
On Sale, Electrical-DC/Low Frequency DMM-918
Q1 Reduced Pricing!

5.5 Digital Multimeter

The primary purpose of this ILC/PT is to determine the appropriateness and effectiveness of participant practices, training, and measurement uncertainty relating to the calibration of a 5.5 Digit Multimeter (DMM).

Participants in this ILC will use their established methods and procedures to perform a pre-determined set of 19 measurements across the ranges and functions of a 5.5 DMM, to include measurement of AC Voltage, DC Voltage, AC Current, DC Current, Resistance, and Frequency.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Enroll
On Sale, Other Mechanical MASS-101
Q1 Reduced Pricing!

Mass Weight Set

This program is intended to provide a means for the participant laboratory to validate the technical competence of the laboratory in the calibration of small weights. This ASTM Class 1 weight kit contains 9 items ranging from 1 g to 100 g.

Reference values and associated uncertainties are provided by an accredited laboratory who concentrates on these measurements. Reference uncertainties vary from 1.6 µg to 12 µg depending on size.

Participants are expected to be familiar with handling and calibration of precision weights and have appropriate lab equipment and  measurement uncertainties for calibration of similar weights.

Show Details Enroll
On Sale, Thermodynamic TEMP-IR-114
Q1 Reduced Pricing!

IR Thermometer

The intent of this ILC/PT is to provide a means for the participant lab to determine the appropriateness and effectiveness of practices, training, and measurement uncertainty relating to the ability of the lab to generate and measure infrared temperatures using a calibrated infrared thermometer. The participant infrared standard will be used as a source for all measurements.

This ILC/PT Kit contains an IR Thermometer with 0.1 °C resolution and 1% / 1 °C (whichever is greater) accuracy spec. Participants are asked to use their lab practices to make 5 measurements of temperature between -20 °C and 750 °C.

Participants are expected to be familiar with, and have appropriate lab equipment and measurement uncertainties for calibration of similar devices.

Show Details Enroll

Theme picker

Proficiency Testing is Crucial

Proficiency testing plays a vital role in a lab’s quality assurance efforts and is required by major accrediting bodies. Routine testing can also benefit your lab in multiple other ways.

  • Maintain Accreditation
  • Ensure Technical Competence
  • Uphold Quality Standards
  • Monitor Lab Performance
  • Improve Processes
  • Maintain Accreditation
  • Ensure Technical Competence
  • Uphold Quality Standards
  • Monitor Lab Performance
  • Improve Processes